RO Pure Water Treatment is the most precise membrane liquid separation technology. The operating pressure is applied on the side of the inlet water and the concentrated solution to overcome the natural osmotic pressure.
When the operating pressure higher than the natural osmotic pressure is dropped on the side of the concentrated solution water molecules naturally permeate the flow The direction will be reversed, and the water molecules in the influent concentrated solution pass through the reverse osmosis membrane to become the purified water om the dilute solution side Reverse osmosis suitable equipment can block all soluble salts and organic substances with a molecular weight greater than 100. but allow water molecules to pass through, The salt rejection rate of reverse osmosis composite membranes is generally greater than 98%.
RO 순수 처리
Most of our projects use DOW Filmtec, Toray, Vontron, Hydranautics, LG brands. They are well-known brands in the water treatment industry.
The reverse osmosis membrane is the core element to realize reverse osmosis, and it is an artificial semipermeable membrane with certain characteristics made by simulating biological semipermeable membrane. Generally made of polymer materials. Such as cellulose acetate film, aromatic polyhydrazide film, aromatic polyamide film. The diameter of the surface pores is generally between 0.5 and 10 nm, and the permeability is related to the chemical structure of the membrane itself. Some polymer materials have good repellency to salt, but the permeation speed of water is not good. The chemical structure of some polymer materials has more hydrophilic groups, so the permeation speed of water is relatively fast. Therefore, a satisfactory reverse osmosis membrane should have an appropriate amount of permeation or salt rejection.
Additionally, commercial RO water treatment systems can incorporate chemicals such as anti-scaling (scaling inhibitors), anti-fouling, pH adjustment, sterilization and disinfection chemicals in the pre- or post-treatment. We keep a close eye on the water treatment industry and add new water technologies to our reverse osmosis water plants.
When checking the customer's water quality analysis report, sometimes due to scaling and scaling problems, we can use the CIP (cleaning-in-place) system to clean the membrane in the membrane shell to make the membrane longer life. It is a new type of water treatment technology most used in the water treatment industry.
상업용 RO 수처리 시스템의 전력
상업용 정수 설비의 경우 220-380V/50Hz/60Hz가 필요합니다. 특히 산업용 역삼투압 시스템의 경우 고압 펌프로 인해 380V 50/60Hz가 필요합니다. 상업용 역삼투 정수 기계 설계와 관련하여 전기 공급을 확인하고 전원을 수정하기로 결정합니다. 더구나, 우리는 전기 비용을 삭감하는 몇몇 에너지 절약 방법이, Chunke 새로운 물 처리 기술 당신이 운영하는 체계를 위한 당신의 가장 큰 비용을 삭감하는 것을 돕습니다 있습니다.
상업용 정수 시스템을 구입하기 전에 다음을 알아야합니다.
1. 순수한 물 생산 능력 (L/day, L/Hour, GPD).
2. 급수 TDS 및 원수 분석 보고서(오염 및 스케일링 문제 방지)
3. 철과 망간은 익지않는 물이 역삼투 물 여과 막에 들어가기 전에 제거되어야 합니다
4. TSS(Total Suspended Solid)는 상업용 정수 시스템의 멤브레인 전에 제거해야 합니다.
5. SDI(실트 밀도 지수)는 3 미만이어야 합니다.
6. 수원에 기름과 그리스가 없는지 확인해야 합니다.
7. 염소는 상업적인 물처리 시스템의 앞에 제거되어야 합니다
8. 사용 가능한 전력 전압 및 위상
9. 상업적인 RO 역삼투 체계를 위한 장소의 배치상업적인 RO 물처리 시스템을 위한 가동 명세
급수 TDS: 0 - 1000ppm
|
18ppm 이상의 경도는 스케일 방지제 투여가 필요합니다.
|
탁도는 다음과 같아야 합니다.
제거
|
최대 급수 온도: 42°C
|
더 높은 TDS 결과에서 작동 더 낮은
복구
|
H2S는 다음과 같아야 합니다.
제거
|
pH 허용 오차: 3-11
|
최대 철분 함량: 0.05ppm
|
|
급수 압력: 1.5 to 6 bar
|
최대 실리카 내성: 60ppm
|
|
Contact us to learn more about our industrial reverse osmosis systems and commercial RO water plants. Our sales team and technical team will be happy to share new water treatment technologies for your project.